Chamber |
Input Power |
AC220V¡¾10% 50/60§Ô |
Communication method |
USB |
Temperature control |
Automatic temperature control of Preamp and chamber |
Focus |
Precise control by laser |
Sample location |
Settlement of location by laser |
Safety device |
Shutoff of X-ray within 0.5 second of recognizing the door opening during the measurement |
Dose rate |
1§¡Sv or less |
Multi-channel analyzer |
Number of channels |
8K(8192) |
Temperature control |
Preamp with automatic temperature control |
Pulse processing |
Rapid processing using micro computer |
X-Ray Source |
Tube |
Oil Cooling compact point
Micro Focus(option) |
High-voltage current |
0~50kV(program control) |
Tube current |
0~1mA(program control) |
Target |
W(Mo, Be window option) |
Collimator |
Collimator |
Fixed, Option(Automatic, Polycapillary) |
Size of Fixed type |
Selection among 0.1, 0.2, 0.3, 0.4, 0.1x0.4 mm (other sizes available) |
Size of Automatic type |
0.1, 0.2, 0.3, 0.4, 0.05x0.4mm |
Detection System |
Detector |
Proportional Counter, Pin, SDD |
Computer System |
Computer |
IBM Compatible computer |
Monitor |
21 inch LCD monitor |
Printer |
Inkjet color printer |
Measurement of 2D3D and random location |
2D |
Measurement of products or planes with a certain interval |
3D |
Measurement of coating distribution status of a plane |
Random location |
Measurement of products with irregular arrangement |
|
Polycapillary |
 |
Spot Size |
30um / FWHM |
|
|
|
X-Y-Z Stage |
|
|
Activation method |
High speed with flexible adjustment
High precision motor control |
Location control |
Location control by mouse
Location control by stage control window
Point and shop of the camera screen
2D3D, random location window location control
Location control by program
Y-axis movement control by door open & close |
Camera System |
Camera |
Digital CCD color camera |
Display method |
Overlay on the monitor |
Ruler |
Display by software |
Beam |
Display of life-size by software |
Lamp |
Flexible control of brightness |
Automatic adjustment |
Automatic adjustment of Beam axis and camera axis |
Calibration curve |
Application |
Single-layer, double-layer, alloy thickness and ratio, solution |
Correction |
Density correction, background correction by recalibration, correction of standard sample |
Statistical processing |
Processing items |
Maximum, minimum, scope of fluctuation, average, standard deviation, X-bar charge, range chart, histogram |
Report |
Five different types of report |
Number of processing items |
Up to 90 report items |
Logo |
Insertion of corporate logos including picture and text |
Preview |
Preview before printout to prevent unnecessary printout |
Qualitative analysis |
Display method |
Display of spectrum of element |
Method |
Qualitative analysis through ROI range method |
Display of element |
Display of label of designated element |
Magnify |
A desired portion can be magnified |
Avg function |
Soft display of spectrum |
Screen size |
Resizing screen from smallest to the fullest on a continuous basis |
|
|